Microcirculation case analysis:
-
(1) Hypertension: Enter sticks spasm, slender, showing hook-shaped pipe loop. decrease the number of blood vessels, blood flow velocity faster.
-
(2) Coronary artery disease: to decrease the number of loop tube, severe deformity, lower output and papillary venous plexus branch expansion, stasis. Erythrocyte aggregation, slow blood flow, blood plasma separation, severe blood was sand-like.
-
(3) Hypotension: pipe loop hidden, more gentle, stiffness, redness of the skin lighter, slow blood flow or stagnation.
-
(4) Chronic bronchitis, asthma, pulmonary heart disease: decreasing the number of pipe loops, loop short loop or only see the top or disappear, pipe loop deformity, nipple vein dilation, blood flow is slow. Senile chronic bronchitis, which pipe loop than normal, but between milk under severe venous plexus dilatation.
-
(5) Diabetes: pipe loop fuzzy, deformity, the wall is not smooth, common flocculent pipe loop, blood viscosity is high, the flow rate is slow, sometimes dotted line shape.
-
(6) Liver: pipe loop deformity, not smooth, oozing or bleeding, severe red blood cell aggregation, blood flow is slow, severe venous plexus obvious.
-
(7) Peripheral vascular disease (vasculitis): decrease the number of pipe loops, deformity, loop top bleeding, oozing or bleeding, blood flow is slow uneven.
-
(8) Rheumatology: pipe loop length extension spasms disappeared, pulse movement dilated, blood, red blood cell aggregation, thrombosis obvious, slow flow.
-
(9) Kidney Disease: pale background, loop week exudation, bleeding, blood stasis classes, decreasing the number of pipe loops is not clear, uneven thickness, pipe loop tortuous twisting, spasms end arterioles, venules end opposite the relaxation, flow It slowed down.
-
(10) atherosclerosis: pipe loop deformation, distortion, wall coarse "twist" and "cross" shape more and bigger blood viscosity, slow blood flow level.
a) monitor display setting, adjust the contrast to the maximum, and the brightness to mid high range.
b) Put the left ring finger painted less oil (or paraffin oil) on the finger seat, align the bottom of the objective lens, microscope coarse hand wheel rotation, alignment focus, until a clear picture appears on the monitor screen. At the same time, then adjust the monitor's contrast and brightness, with no glare and image clarity as well. (Note: The microscope focusing hand wheel adopts the international advanced common rail coaxial coarse and fine focusing mechanism when the first rotation coarse hand wheel to locate the image, and then fine-tune the hand wheel is adjusted to the image is clear, the focus is very convenient, easy. As found in the coarse handwheel is too loose or too tight, you can rotate the dancer hand rotation properly adjusted, that is, not adjusted to the decline and lift freely.)
Microcirculation case analysis:
(1) Hypertension: Enter sticks spasm, slender, showing hook-shaped pipe loop. Reduce the number of blood vessels, blood flow velocity faster. (2) coronary artery disease: to reduce the number of loop tube, severe deformity, lower output and papillary venous plexus branch expansion, stasis. Erythrocyte aggregation, slow blood flow, blood plasma separation, severe blood was sand-like. (3) hypotension: pipe loop hidden, more gentle, stiffness, redness of the skin lighter, slow blood flow or stagnation. (4) chronic bronchitis, asthma, pulmonary heart disease: reducing the number of pipe loops, loop short loop or only see the top or disappear, pipe loop deformity, nipple vein dilation, blood flow is slow. Senile chronic bronchitis, which pipe loop than normal, but between milk under severe venous plexus dilatation. (5) Diabetes: pipe loop fuzzy, deformity, the wall is not smooth, common flocculent pipe loop, blood viscosity is high, the flow rate is slow, sometimes dotted line shape. (6) Liver: pipe loop deformity, not smooth, oozing or bleeding, severe red blood cell aggregation, blood flow is slow, severe venous plexus obvious. (7) peripheral vascular disease (vasculitis): reduce the number of pipe loops, deformity, loop top bleeding, oozing or bleeding, blood flow is slow uneven. (8) Rheumatology: pipe loop length extension spasms disappeared, pulse movement dilated, blood, red blood cell aggregation, thrombosis obvious, slow flow. (9) Kidney Disease: pale background, loop week exudation, bleeding, blood stasis classes, reducing the number of pipe loops is not clear, uneven thickness, pipe loop tortuous twisting, spasms end arterioles, venules end opposite the relaxation, flow It slowed down. (10) atherosclerosis: pipe loop deformation, distortion, wall coarse "twist" and "cross" shape more and bigger blood viscosity, slow blood flow level. |
|
Microscope material
|
metal 95% + plastic 5%
|
Digital Magnification
|
400x
|
Objective lens
|
10X
|
CCD camera
|
3MP resolution is 2560¡Á1440 (about 3.69 million pixels)
|
LCD screen resolution
|
1024*720 pixels
|
Working height
|
0-25 mm
|
Loading Stage
|
double-layer mechanical platform, X, Y axis
|
Stage size
|
12.5cm*11.5cm
|
Suitcase size
|
34cm*29cm*19cm
|
Suitcase material
|
aluminum alloy + plastic board
|
stage size
|
120 mm x 118 mm
|
Focusing system
|
coarse adjustment + fine adjustment coaxial
|
Lighting
|
LED cold light
|
Output
|
DC12V, 2A
|
Power supply
|
12V, 1A, DC power supply
|
Voltage
|
100V-240V
|
Package weight
|
4.75KG
|
Packing size
|
36*21*32cm
|
Power plug
|
American plug (other plugs can be provided)
|

Certification: