880-68A

2023/9/26 11:22:02
  • Brand Body Testing
  • Model 880-68A
Introduction


Microcirculation case analysis:

  • (1)  Hypertension: Enter sticks spasm, slender, showing hook-shaped pipe loop. decrease the number of blood vessels, blood flow velocity faster.
  • (2)  Coronary artery disease: to decrease the number of loop tube, severe deformity, lower output and papillary venous plexus branch expansion, stasis. Erythrocyte aggregation, slow blood flow, blood plasma separation, severe blood was sand-like.
  • (3)  Hypotension: pipe loop hidden, more gentle, stiffness, redness of the skin lighter, slow blood flow or stagnation.
  • (4)  Chronic bronchitis, asthma, pulmonary heart disease: decreasing the number of pipe loops, loop short loop or only see the top or disappear, pipe loop deformity, nipple vein dilation, blood flow is slow. Senile chronic bronchitis, which pipe loop than normal, but between milk under severe venous plexus dilatation.
  • (5)  Diabetes: pipe loop fuzzy, deformity, the wall is not smooth, common flocculent pipe loop, blood viscosity is high, the flow rate is slow, sometimes dotted line shape.
  • (6)  Liver: pipe loop deformity, not smooth, oozing or bleeding, severe red blood cell aggregation, blood flow is slow, severe venous plexus obvious.
  • (7)  Peripheral vascular disease (vasculitis): decrease the number of pipe loops, deformity, loop top bleeding, oozing or bleeding, blood flow is slow uneven.
  • (8)  Rheumatology: pipe loop length extension spasms disappeared, pulse movement dilated, blood, red blood cell aggregation, thrombosis obvious, slow flow.
  • (9)  Kidney Disease: pale background, loop week exudation, bleeding, blood stasis classes, decreasing the number of pipe loops is not clear, uneven thickness, pipe loop tortuous twisting, spasms end arterioles, venules end opposite the relaxation, flow It slowed down.
  • (10) atherosclerosis: pipe loop deformation, distortion, wall coarse "twist" and "cross" shape more and bigger blood viscosity, slow blood flow level.


a) monitor display setting, adjust the contrast to the maximum, and the brightness to mid high range.

b) Put the left ring finger painted less oil (or paraffin oil) on the finger seat, align the bottom of the objective lens, microscope coarse hand wheel rotation, alignment focus, until a clear picture appears on the monitor screen. At the same time, then adjust the monitor's contrast and brightness, with no glare and image clarity as well. (Note: The microscope focusing hand wheel adopts the international advanced common rail coaxial coarse and fine focusing mechanism when the first rotation coarse hand wheel to locate the image, and then fine-tune the hand wheel is adjusted to the image is clear, the focus is very convenient, easy. As found in the coarse handwheel is too loose or too tight, you can rotate the dancer hand rotation properly adjusted, that is, not adjusted to the decline and lift freely.)





Why this model?

Microcirculation case analysis:
(1) Hypertension: Enter sticks spasm, slender, showing hook-shaped pipe loop. Reduce the number of blood vessels, blood flow velocity faster.
(2) coronary artery disease: to reduce the number of loop tube, severe deformity, lower output and papillary venous plexus branch expansion, stasis. Erythrocyte aggregation, slow blood flow, blood plasma separation, severe blood was sand-like.
(3) hypotension: pipe loop hidden, more gentle, stiffness, redness of the skin lighter, slow blood flow or stagnation.
(4) chronic bronchitis, asthma, pulmonary heart disease: reducing the number of pipe loops, loop short loop or only see the top or disappear, pipe loop deformity, nipple vein dilation, blood flow is slow. Senile chronic bronchitis, which pipe loop than normal, but between milk under severe venous plexus dilatation.
(5) Diabetes: pipe loop fuzzy, deformity, the wall is not smooth, common flocculent pipe loop, blood viscosity is high, the flow rate is slow, sometimes dotted line shape.
(6) Liver: pipe loop deformity, not smooth, oozing or bleeding, severe red blood cell aggregation, blood flow is slow, severe venous plexus obvious.
(7) peripheral vascular disease (vasculitis): reduce the number of pipe loops, deformity, loop top bleeding, oozing or bleeding, blood flow is slow uneven.
(8) Rheumatology: pipe loop length extension spasms disappeared, pulse movement dilated, blood, red blood cell aggregation, thrombosis obvious, slow flow.
(9) Kidney Disease: pale background, loop week exudation, bleeding, blood stasis classes, reducing the number of pipe loops is not clear, uneven thickness, pipe loop tortuous twisting, spasms end arterioles, venules end opposite the relaxation, flow It slowed down.
(10) atherosclerosis: pipe loop deformation, distortion, wall coarse "twist" and "cross" shape more and bigger blood viscosity, slow blood flow level.
Microscope material
metal 95% + plastic 5%
Digital Magnification
400x
Objective lens
10X
CCD camera
3MP resolution is 2560¡Á1440 (about 3.69 million pixels)
LCD screen resolution
1024*720 pixels
Working height
0-25 mm
Loading Stage
double-layer mechanical platform, X, Y axis
Stage size
12.5cm*11.5cm
Suitcase size
34cm*29cm*19cm
Suitcase material
aluminum alloy + plastic board
stage size
120 mm x 118 mm
Focusing system
coarse adjustment + fine adjustment coaxial
Lighting
LED cold light
Output
DC12V, 2A
Power supply
12V, 1A, DC power supply
Voltage
100V-240V
Package weight
4.75KG
Packing size
36*21*32cm
Power plug
American plug (other plugs can be provided)

Certification:

Microcirculation detector HD flow rate finger circulation tester blood observation instrument portable microscope