PH-803W PH/ORP LED

2023/7/13 16:48:00
  • 产品品牌 水质检测
  • 产品型号 PH-803W PH/ORP LED
产品介绍

Please note:

PH-803W, APP software can scan this QR code to download the QR code download password is: 778856 currently only supports Android system download and use temporarily does not support Apple terminal, if you need video of application software installation, please contact me, provide your email, I will send APP software and APP software installation video to you to help you install, connect to the phone and use the product.
The language is linked to the version of the mobile phone system. If the system language is adjusted to international version, the language will be automatically adjusted to request English
Do not soak the ORP electrode for a long time, otherwise the ORP electrode will be damaged, please pay attention!


PH-803W The Internet of Things PH & amp; ORP regulator

PH-803W is a new digital wifi monitoring acid-base and redox controller which can measure and display the pH value and redox value (ORP) at the same time. It has 2 BNC electrodes (pH and redox) and 2 output sockets. It has fast response speed and easy pH calibration. The two electrodes are detachable and can be easily replaced at any time without the need to purchase and replace the entire device. At the same time control other equipment related to pH and ORP to adjust pH and ORP value in liquid. Precisely, easily and automatically monitor and control pH and ORP values and other control equipment related to pH and ORP. With strict quality and safety certification, it can ensure reliability, stability, long service life and trouble-free service life, and is easy to carry, using the dead zone protection function when When using or installing the device, you can choose to mount it to the wall or hang it in a solution container. The types of products are: 110V and 220V.

Has applications and uses:

Fish farms, wine production, swimming pools (bathrooms), laboratories, water treatment, schools and colleges, florists, for liquid analysis (ph), ponds, various industrial applications, swimming pools, koi, Cois , Boyrel, pond, swimming pool, spa, swimming pool, swimming pool, analysis of liquids, Reproduction of orchids, breeding, culture, etc. The correct method allows you to pay attention to the different parameters of the water in the tank at all times! There has to be a perfect way to automate and adjust aquarium controls to remove dead water and maintain a healthy water system.

Technical specification:

1. Model: PH-803W
Range:
PH: 0.00 ~ 14.00PH
ORP: -1999 ~ 1999mV
Precision:
PH: ± 0.05PH
ORP: ± 5 mV
Resolution:
PH: 0.01PH
ORP: 1mV
Defined range:
PH: 0.00 ~ 19.99PH
ORP: -1999 ~ 1999mV
2. Ambient temperature: 0 ~ 50 ℃ humidity <95 +
3.Display: dual LCD display 4 reading
4.Power supply: 220V ± 10 × 50Hz ± 2 ×
5. Dimensions: 160mm × 102mm × 40mm
6. Weight: 870g

Surgery:

1. AC power connection (Make sure the voltage is correct.)
2. Connect the PH and ORP electrode into the input terminal socket respectively.
3. Remove the protective cap and observe if the electrodes are clean and complete (note: do not touch the electrodes with your hands).
4. After cleaning the electrodes with distilled water or alcohol, dry the water on the plastic case and shake the small droplets on the electrodes, insert the device into the solution under test so that the electrodes measurement are immersed in the solution tested, and the immersion depth of the electrodes must not exceed the length of the electrodes.
5. Place the electrodes in the measured solution to be tested.
6. Gently shake the device so that small bubbles on the electrodes leave the electrodes and read a stable display number when the value is stable.
7. After use, turn off the power supply, clean the electrodes with clean water and put on a protective cap.
8. It should be used for a long time, and the device and electrode should be fixed.

Calibration:

Calibration pH:
A. In pH6.86 Calibration solution
1. Connect AC power. Immerse the ph electrode in a pH6.86 buffer solution and shake it gently until the reading stabilizes.
2. Long press [b], until the “pH” indicator flashes. PH6.86 is displayed on the first line.
3. (1) Short press [a] to exit current mode if ph6.86 calibration is not performed. Then the device returns to measuring mode.
(2) Short press [c] to complete the pH 6.86 calibration when the second line reading is stable if the pH6.86 calibration is performed. The device then automatically returns to measuring mode.
4. The pH6.86 calibration is complete.
B. In pH4.00 Calibration solution
1. Connect the AC power. Immerse the ph electrode in a pH 4.00 buffer solution and shake it gently until the reading stabilizes.
2. Long press [e], until the “pH” indicator flashes. pH 4.00 is displayed on the first line.
3. (1) Short press [a] to exit current mode if pH 4.00 calibration is not performed. Then the device returns to measuring mode.
(2) Short press [c] to complete the pH 4.00 calibration when the second line reading is stable if the ph4.00 calibration is performed. The device then automatically returns to measuring mode.
4. The pH 4.00 calibration is complete.
ORP calibration:
This meter has been precisely precalibrated for mV range at the factory. And there is no need for users to calibrate.

Packing list:

1 double aquarium controller for pH and ORP (available in 110V or 220V)
1x300cm detachable pH electrode
1x300cm detachable ORP electrode
2 x rubber cable holder with suction cap
1 x metal wall hanger
1 x mini screwdriver
1 x English instruction manual

Note for PH-803W :

1. The electrode must be calibrated with a standard buffer solution with known ORP value before measurement.
2. The electrode socket must be highly marked and dry.
3. Before and after the measurement, the electrode should be cleaned with deionized water to ensure the measurement accuracy.
4. The electrode will be passivated after long-term use. The phenomenon is that the sensitivity gradient decreases, the response becomes slow, and the reading is inaccurate. At this time, the platinum sheet at the bottom of the electrode can be soaked in 0.1M dilute hydrochloric acid for 24 hours, and then use 3Mkcl solution. Soak in medium for several hours to restore performance.
5. Electrode contamination or blockage of the liquid junction will also passivate the electrode. At this time, it should be cleaned with an appropriate solution according to the nature of the pollutant. See below (for reference) for details.
a. Contaminant cleaning materials
b. Inorganic metal oxide
c. less than 1M dilute hydrochloric acid
d. Organic oils and fats
e. Dilute detergent resin polymer substance dilute alcohol, acetone, ether, protein blood cell precipitate acid enzyme solution
f. Pigment substances dilute bleach, hydrogen peroxide
6. The electrode life cycle is about one year, and the new electrode should be replaced in time after aging.

Please note:

PH-803W application software and application software installation video, only monitoring software is Android system, currently there is no Apple terminal, if necessary, please contact me, provide your email, I will send the software from the application and application software for you to install the video to help you install, link to your phone, and use the product.

PH-803W Internet of Things PH and ORP Controller

KL-803W is a new wifi digital monitoring acid-base and redox controller that can measure and display pH value and redox value (ORP) at the same time. It has 2 BNC electrodes (pH and redox) and 2 output sockets. It has a fast response speed and easy pH calibration. Both electrodes are detachable and can be easily replaced at any time without the need to purchase and replace the entire device. At the same time, it controls other pH and ORP related equipment to adjust the pH and redox value in the liquid. Accurately, easily and automatically monitor and control pH and ORP values and other pH and ORP related control equipment. Through strict quality certification and safety standard, it can guarantee reliability, stability, long service life and trouble-free, And it is easy to carry, using the dead zone protection function when using or installing the unit, you can choose to mount it on the wall or hang it in a solution container. The product types are: 110 V and 220 V.

更多产品